中、高压锅炉补给水处理设备

时间:2018/3/22 16:49:18 作者:静波环保 分享到:

未标题-1.jpg

中、高压锅炉补给水处理设备是保障锅炉安全运行的关键系统,通过多级工艺去除水中杂质,满足不同压力等级锅炉对水质的高标准要求。以下是其核心技术与应用解析:

一、核心处理工

1、‌预处理阶段‌

多介质过滤+活性炭吸附,去除悬浮物、胶体及余氯。

软化处理(钠离子交换)降低硬度,适用于中压锅炉。

2、‌深度脱盐技术‌

‌反渗透(RO)‌:脱盐率≥98%,产水电导率≤10μS/cm,适用于高压锅炉。

‌EDI(电去离子)‌:无需化学再生,连续产水,适合超纯水需求。

3、‌辅助系统‌

自动循环清洗装置:延长RO膜寿命。

PLC/DCS控制系统:实时监测水质参数(如pH、电导率)并自动调节。

二、设备优势

1、‌高效稳定‌

采用静波反渗透膜元件,产水水质稳定达标。

故障率低,科学化管理程度高。

2、‌节能环保‌

无盐池设计,减少占地面积与额外开销。

回收率可达80%,降低排污量。

3、‌智能化操作‌

全自动运行,仅需监测电脑显示屏


三、典型应用场景

.‌热电厂‌:20T/H锅炉补给水系统案例显示,RO+EDI工艺可满足亚临界锅炉需求。

.‌化工厂‌:处理高盐废水后回用于高压锅炉,降低结垢风险。


The supply water treatment equipment for medium and high pressure boilers is a key system to ensure the safe operation of boilers. Through multi-stage processes, impurities are removed from the water to meet the high water quality requirements of boilers of different pressure levels. The following is an analysis of its core technologies and applications:

Core Processing Worker

1. Preprocessing stage

Multi media filtration+activated carbon adsorption to remove suspended solids, colloids, and residual chlorine.

Softening treatment (sodium ion exchange) reduces hardness and is suitable for medium pressure boilers.

2. Deep desalination technology

Reverse osmosis (RO): desalination rate ≥ 98%, water conductivity ≤ 10 μ S/cm, suitable for high-pressure boilers.

EDI (Electrodeionization): No chemical regeneration required, continuous water production, suitable for ultra pure water demand.

3. Auxiliary system

Automatic cycle cleaning device: prolongs the lifespan of the RO membrane.

PLC/DCS control system: Real time monitoring of water quality parameters (such as pH, conductivity) and automatic adjustment.

Equipment advantages

1. Efficient and stable

Using static wave reverse osmosis membrane components, the water quality of the produced water is stable and meets the standard.

Low failure rate and high degree of scientific management.

2. Energy conservation and environmental protection

Salt free pond design reduces land occupation and additional expenses.

The recovery rate can reach 80%, reducing the amount of pollutants discharged.

3. Intelligent operation

Fully automatic operation, only requiring monitoring of the computer display screen


Typical application scenarios

Thermal power plant: A case study of a 20T/H boiler feedwater system shows that the RO+EDI process can meet the requirements of subcritical boilers.

Chemical plant: After treating high salt wastewater, it is reused in high-pressure boilers to reduce the risk of scaling.

版权所有: 转载请注明出处